產品詳情
簡單介紹:
德國Endress+Hauser(E+H) PMP51-9LA0/101 壓力變送器,德國原裝。
供電電壓:10.5——45V DC
精度: 0,075%
測量范圍:100mbar...700bar
輸出: 4...20mA 、PROFIBUS PA
。
詳情介紹:
德國e+h 壓力變送器PMP51-9LA0 101
德國Endress+Hauser(E+H) PMP51-9LA0/101 壓力變送器,德國原裝。
供電電壓:10.5——45V DC
精度: 0,075%
測量范圍:100mbar...700bar
輸出: 4...20mA 、PROFIBUS PA
Endress+Hauser公司致力于為化工、石油和天然氣、食品與飲料、水與污水處理、能源、冶金、造紙、造船與環境檢測等廣泛的行業領域提供**的產品和服務。憑借全球完整的自動化儀表生產線,Endress+Hauser可為客戶量身定做合適的自動化解決方案
技術參數Pressure
1.測量原理: Hydrostatic
Characteristic Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functionsSecondary process barrier
2.Supply / Communication: 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:9...32V DC
3.Accuracy 0,075%
"PLATINUM" 0,05%
Long term stability 0,05% of URL/year
Process temperature -40°C...125°C
(-40°F...257°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
4.Measuring range 100mbar...700bar
(1.5psi...10.500psi)
5.Max. overpressure: limit 1050bar (15.750psi)
Process connection Threads
Flanges (DIN, ANSI, JIS, ...) with flush membrane
6.Output 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
7.Certificates / Approvals ATEX
FM
CSA
TIIS
NEPSI
IECEx
SIL
NACE
GL marine
WHG/ Overfill prevention
EN10204-3.1
8.Options: HistoROM/M-Dat,4-line digital display
9.SS- or Aluminiumhousing
Separate housing
Specialities diagnostic functions
德國Endress+Hauser(E+H) PMP51-9LA0/101 壓力變送器,德國原裝。
供電電壓:10.5——45V DC
精度: 0,075%
測量范圍:100mbar...700bar
輸出: 4...20mA 、PROFIBUS PA
Endress+Hauser公司致力于為化工、石油和天然氣、食品與飲料、水與污水處理、能源、冶金、造紙、造船與環境檢測等廣泛的行業領域提供**的產品和服務。憑借全球完整的自動化儀表生產線,Endress+Hauser可為客戶量身定做合適的自動化解決方案
技術參數Pressure
1.測量原理: Hydrostatic
Characteristic Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functionsSecondary process barrier
2.Supply / Communication: 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:9...32V DC
3.Accuracy 0,075%
"PLATINUM" 0,05%
Long term stability 0,05% of URL/year
Process temperature -40°C...125°C
(-40°F...257°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
4.Measuring range 100mbar...700bar
(1.5psi...10.500psi)
5.Max. overpressure: limit 1050bar (15.750psi)
Process connection Threads
Flanges (DIN, ANSI, JIS, ...) with flush membrane
6.Output 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
7.Certificates / Approvals ATEX
FM
CSA
TIIS
NEPSI
IECEx
SIL
NACE
GL marine
WHG/ Overfill prevention
EN10204-3.1
8.Options: HistoROM/M-Dat,4-line digital display
9.SS- or Aluminiumhousing
Separate housing
Specialities diagnostic functions